Lightning Ground aboard Gray Eagle a Tashiba 40 A few years ago I was anchored in Hamburg Cove, Connecticut. It was just after dinner and getting dark when the weather turned ugly. The cove is very protected with high bluffs on two sides. A serious summer thunderstorm rolled in and produced the worst lightning I have ever seen or heard. Reluctantly, I peered out the ports to watch the light show and could see the bolts hitting the trees just a hundred yards away. When it was over I felt lucky not to be a victim of the squall especially since I was sitting in salt water with a 50 foot aluminum mast challenging the All Mighty. There have been many other close encounters with lightning and finally a hit when the boat was on our home mooring. Actually the boat five moorings away took it direct and we must have only experienced a minor hit. Most of the electronics were either serviced or replaced during the next two seasons as they either failed completely or had strange intermittent problems. What I found is that you do not have to get a direct strike in order to have damage and the damage may not be immediately noticed. It can take some time for all the stressed circuits and electronic components to finally give up the ghost. This is especially unfortunate because the insurance company wants to see the proof and not hear anything about, “I might have been hit by lightning two years ago”. This makes it impossible to submit a claim for lightning damage even though the total cost can be significant. With all this lightning experience in the ships log I started looking into how Gray Eagle was wired for lightning protection and what the latest recommendations are by ABYC and the (1-see below) NFPA 780. TaShing Yacht Building, Ltd. wired the Tashiba 40 in accordance with the standards and understanding of lightning protection at the time which was 1987. This consisted of linking all the bronze through-hulls, rigging and tanks with green grounding wire. This circuit also serves as the bonding circuit and is connected to the zincs and one wire to DC negative battery. The new recommendations call for a strip of copper bolted to the hull measuring at least 4 feet long and at least ¾ inch wide and 3/16 inch thick with one end under the mast and the other near the engine. If these exact dimensions can not be accommodated the NFPA says the copper plate must have at least 1 ft sq area x 3/16 inch thickness. The copper strip must be below the water line at all times and most importantly located directly below the mast. Attachment must be with bolts equivalent to a #4 AWG cable. There are a few more details but this is basically what one must start with. On the Tashiba 40 it’s impossible to comply with the suggested 4 foot long strip of copper without tearing apart the interior to access the attaching bolts for the copper strip. Therefore an alternate shape must be worked out based on the best way to bolt through the hull in the area below the mast. After much planning I decided on a copper plate 33 inches long x 6 inches wide and ¼ inch thick. These dimensions slightly exceed the recommended area of 1 foot sq x 3/16 thick. I arrived at the 33 inch length by spanning the mast step fore and aft with one bolt in front of the mast step and one behind it on the port side. The copper plate uses two ½ inch diameter x 3 inches long, silicon bronze carriage bolts. Carriage bolts require the hole drilled into the copper plate to be squared off. This keeps the bolt from turning while torquing down the nut. Heavy duty silicon bronze nuts along with lock washers and big flat washer are used inside the boat to secure the assembly. The cable connection between mast and carriage bolts is made by drilling and taping a ¼ x 20 thread in the mast just above the mast step and below the exit hole for the mast wiring. Two battery cables size 1Ø competes the grounding of the mast to the copper plate outside the hull. I feel the low ¼ inch profile will have very little impact on hydrodynamics compared to the traditional Dynaplate. When I installed the copper plate I used 3M, 5200 around the perimeter as an adhesive backup to the ½” diameter carriage bolts and to cut down on turbulence as water flows past the plate. Bedding with 5200 may be a little aggressive and I’m not sure I would use this product around the edges of the copper plate again as this plate will definitely have to be replaced someday and getting it off may be difficult. When bedding anything to the outside of the hull the bottom paint must be removed for good adhesion. So, please be sure to sand away the paint in the area where the copper ground will be. I held the plate up and used a magic marker to outline the plate and sanded down to the barrier coat inside the marks. In addition to using the copper plate as a lightning ground I will connect the 3 inch wide copper foil from the single sideband radio and tuner and use it as a radio ground. This should establish an excellent connection with the water and improve radio transmit performance. Originally, there was no provision by the manufacturer for a radio ground. In the end I hope to accomplish a safer boat when the lightning does show up again. On Long Island Sound, during the summer, I will definitely have the opportunity to test my work and will let you all know how it goes. Richard Cassano S/V Gray Eagle, Tashiba 40 Oyster Bay, NY USA REFERENCE: (1) National Fire Protection Association publication “NFPA 780 Standard for the Installation of Lightning Protection Systems 1997 Edition”